LSI SAS2 Following fields of IOC Page 6 specify the configuration, SAS and Sata hard disk drives

Models: SAS2

1 42
Download 42 pages 37.05 Kb
Page 34
Image 34

Appendix A: Commands

SAS2 Integrated RAID Solution User Guide

The disk identified by the first Enclosure:Bay on the command line becomes the primary disk drive when you create an Integrated Mirroring (RAID 1) volume. If the controller resynchronizes the disk drives, the data on the primary disk drive becomes available when you access the newly created volume.

When the IR firmware creates a RAID 1 volume, it starts a background initialization of the volume. You can use the STATUS command to monitor the status of

the initialization.

Observe the following rules when creating Integrated RAID volumes and hot spare disks:

All disks that are part of a volume, including hot spares for that volume, must be on

 

the same SAS2 controller.

 

You can create RAID 0, RAID 1, RAID 1E, and RAID 10 Integrated RAID volumes.

 

You can create a maximum of two Integrated RAID volumes per controller.

 

The configuration of the Integrated RAID firmware determines the maximum and

 

minimum number of drives that you can use in Integrated RAID volumes. The

 

following fields of IOC Page 6 specify the configuration:

 

MaxDrivesRAID0, MaxDrivesRAID1, MaxDrivesRAID10, MaxDrivesRAID1E

 

MinDrivesRAID0, MinDrivesRAID1, MinDrivesRAID10, MinDrivesRAID1E,

 

MaxVolumes, MaxPhysDisks, MaxGlobalHotSpares, MaxPhysDisks (maximum

 

number of physical drives combined in all volumes on the controller)

 

For more information, refer to the description of the IOC configuration pages in the

 

Fusion MPT 2.0 MPI Specification Guide.

 

SAS2IRCU does not allow you to create an Integrated RAID volume that combines

 

SAS and SATA hard disk drives.

 

SAS2IRCU does not allow you to create an Integrated RAID volume that combines

 

SSDs (solid-state drives) and hard disk drives.

 

SAS2IRCU does allow you to use both SATA and SAS solid-state drives in a single

 

Integrated RAID volume, if the Integrated RAID firmware supports it. Support for

 

such a mixing is specified by values in static fields in Manufacturing Page 4 in the

 

MPI2 specification and is specific for SSD drives only.

Command Line

sas2ircu <controller_#> create <volume_type> <size>

 

{<Enclosure:Bay>} [VolumeName] [noprompt]

Parameters

<controller_#> – The index of the controller for the newly created volume.

 

<volume_type> – Volume type for the new volume. Valid values are RAID0,

 

RAID1, RAID10, or RAID1E.

 

<size> – Size of the RAID volume in Mbytes, or MAX for the maximum size

 

available.

 

<Enclosure:Bay> – The Enclosure:Bay value of the disk drive for the new RAID

 

volume. You can get these values from the output of the DISPLAY command. DOS

 

does not support addressing by Enclosure:Bay.

 

VolumeName A user-specified string to identify the volume.

 

noprompt – This optional parameter prevents warnings and prompts from

 

appearing while the command is running.

Page 34

LSI Corporation Confidential August 2010

Page 34
Image 34
LSI SAS2 Following fields of IOC Page 6 specify the configuration, SAS and Sata hard disk drives, RAID1, RAID10, or RAID1E