LSI SAS2  Volume status Enabled or Disabled,  Physical disk I/Os Quiesced or Not quiesced, None

Models: SAS2

1 42
Download 42 pages 37.05 Kb
Page 39
Image 39

SAS2 Integrated RAID Solution User Guide

Appendix A: Commands

Sample Output Following is an example of the information that the STATUS command returns when a volume resynchronization is in progress:

Background command progress status for controller 0...

IR Volume 1

: 6

Volume ID

Current operation

: Synchronize

Volume status

: Enabled

Volume state

: Degraded

Physical disk I/Os

: Not quiesced

Volume size (in sectors)

: 70311936

Number of remaining sectors

: 68250624

Percentage complete

: 2.93%

Following is an example of the status information that the STATUS command returns if a background volume operation is not in progress:

Background command progress status for controller 0...

IR Volume 1

: None

Current operation

Volume ID

: 6

Volume status

: Enabled

Volume state

: Optimal

Physical disk I/Os

: Not quiesced

The possible values for the fields in the status data are as follows:

Current operation: Synchronize, Consistency Check, OCE, Background Init, or None

Volume status: Enabled or Disabled

Volume state: [Inactive] Optimal, Degraded, Missing, or Failed

Physical disk I/Os: Quiesced or Not quiesced

A.3.7 LIST Command

The LIST command displays a listing of all controllers present in system, along with

 

 

each corresponding controller index. You use the controller index as an input

 

 

 

 

parameter for other SAS2IRCU commands.

 

 

 

Command Line

sas2ircu list

 

 

 

 

 

Parameters

None

 

 

 

 

 

 

Program Return Value

0x00 SUCCESS: Command completed successfully.

 

 

 

 

0x01

FAILURE: Command failed.

 

 

 

 

 

0x02 ADAPTER_NOT_FOUND: Cannot find specified adapter.

 

 

Sample Output

Following is an example of the output of the LIST command. The format and fields in

 

 

the output may vary depending on the types of installed controllers.

 

 

 

Index

Adapter

Vendor Device

Pci Address

SubSys

SubSys

 

 

Type

ID

ID

Ven ID

Dev ID

 

 

----- --------- ------ ------ ----------------

-------

------

 

 

0

SAS2008

1000h

72h

00h:01h:00h:00h

1000h

00dah

 

 

1

SAS2008

1000h

72h

00h:05h:00h:00h

1000h

00dah

LSI Corporation Confidential August 2010

Page 39

Page 39
Image 39
LSI SAS2 manual  Volume status Enabled or Disabled,  Physical disk I/Os Quiesced or Not quiesced, Sas2ircu list, None