SAS2 Integrated RAID Solution User Guide

Chapter 2: Overview of Integrated RAID Mirrored Volumes Operation of Mirrored Volumes

Integrated Mirroring Volume

Primary

Mirror

 

 

 

 

 

 

 

 

SAS

 

 

 

 

 

 

 

Memory Bus

 

 

 

 

 

LSI

 

 

 

Fusion-MPT

 

 

 

 

 

 

 

SAS2 Controller

 

 

 

 

 

 

 

 

 

NVSRAM

(For Write Journaling)

FLASH

(For Configuration)

3_00006-00

Figure 1: Typical Integrated Mirroring Implementation

The following figure shows the logical view and physical view of an Integrated Mirroring volume. Each logical block address (LBA) is mirrored on the second disk.

Logical View

 

Physical View

LBA 1

LBA 1

LBA 1'

LBA 2

LBA 2

LBA 2'

LBA 3

LBA 3

+

LBA 3'

LBA N

LBA N

LBA N’

3_00007-00

Figure 2: Integrated Mirroring Volume

You can configure an Integrated Mirroring Enhanced volume with up to 10 mirrored disks. The following figure shows the logical view and physical view of an Integrated Mirroring Enhanced volume with three mirrored disks. The firmware writes each mirrored stripe to a disk and mirrors it to an adjacent disk. RAID 1E is another term for this type of mirrored configuration.

LSI Corporation Confidential August 2010

Page 9

Page 9
Image 9
LSI SAS2 manual Typical Integrated Mirroring Implementation