Lucent Technologies 585-210-940 manual Troubleshooting, Error Messages Continued, Message Response

Models: 585-210-940

1 106
Download 106 pages 54.9 Kb
Page 100
Image 100
Manual background

Troubleshooting

CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems

Error messages

94

 

 

Error Messages (Continued)

Message:

Explanation:

Response:

The disk is not recognized by cms.

The disk is either not a standard Sun disk drive, or is larger than 4.2 gigabytes.

Replace the disk with a standard Sun disk drive of not more than 4.2 gigabytes capacity.

Message:

Response:

The DiskSuite Software must be installed

to run this script.

Install Solstice DiskSuite software before attempting to run this script.

Message:

Explanation:

Response:

The file filename could not be restored.

The previous action failed, and the md.tab or vfstab file could not be copied back. The existing files may not accurately reflect the system environment.

Check the file and repair it if necessary. See “How to Set Up State Database Replicas” in Chapter 3.

Message:

Explanation:

Response:

The /cms filesystem needs to be mounted

/cms must be mounted for the command to work.

Mount /cms with the command: mount /cms

Page 100
Image 100
Lucent Technologies 585-210-940 Troubleshooting, Error Messages Continued, Message Explanation Response, Message Response