Lucent Technologies 585-210-940 manual Error messages, Troubleshooting, Error Messages

Models: 585-210-940

1 106
Download 106 pages 54.9 Kb
Page 94
Image 94
Error messages

Troubleshooting

CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems

Error messages

88

 

 

Error messages

The table that follows lists and explains error messages you can receive related to Solstice DiskSuite and disk mirroring. The messages are presented in alphabetical order, ignoring special characters and replacement strings. (For example, you would find the message filename restored” in alphabetical order by the word restored.)

Error Messages

Message:

Explanation:

Response:

All data on cms filesystems will be removed and filesystems will be unmirrored, are you sure?

Standard warning message for olds -mirrored-cleanupcommand.

Always use an olds -mirrored -cleanup with caution, keeping in mind that a backup will be needed to recover any CMS data in the /cms filesystem. Use the command only to set up your system from scratch.

Message:

Explanation:

Response:

Attempt an operation on a submirror that

has erred components.

Component needs maintenance before the operation can be carried out.

1.Execute a metastat command.

2.Examine the output for the Invoke line and execute the command named in that line. For example:

#metareplace -e d13 c0t0d0s0

3.Reboot system.

Message:

Explanation:

Response:

CDROM must not be present, remove CD

In order for the command to execute, the CDROM drive must be empty.

1. Enter the command: eject cdrom

2.Remove the CD from the drive tray.

3.Close the drive tray.

Page 94
Image 94
Lucent Technologies 585-210-940 manual Error messages, Troubleshooting, Error Messages, Message Explanation Response