Installing Mirrored Systems | CentreVu CMS Release 3 Version 8 | |
How to upgrade an Enterprise platform to disk mirroring | 25 | |
|
|
|
Step 10: Verify disk space
1.Display available disk space by entering a df
Filesystem | kbytes | used | avail | capacity | Mounted on |
/dev/md/dsk/d13 | 1039555 | 355366 | 580239 | 38% | / |
/proc | 0 | 0 | 0 | 0% | /proc |
fd | 0 | 0 | 0 | 0% | /dev/fd |
swap | 1305272 | 344 | 1304928 | 1% | /tmp |
/dev/md/dsk/d21 31956788 | 849300 | 31107488 | 3% | /cms | |
|
|
|
|
|
|
The figures on the /dev/md/dsk/d21 line are critical. You will use them to determine whether Solstice DiskSuite* is administering all your disks.
2.Complete the table below by filling in (1a) and (1b) as instructed.
Disk Space Verification
Total No. | /cms size in MB | /cms size in MB |
|
of Disks |
| ||
|
|
|
|
2 | 3104 | 6208 |
|
|
|
|
|
4 | 7137 | 14274 |
|
|
|
|
|
6 | 11170 | 22340 |
|
|
|
|
|
8 | 15203 | 30406 |
|
|
|
|
|
10 | 19236 |
|
|
|
|
|
|
Calculations:
(1a) Enter /cms line’s ‘kbytes’ figure divided by 1000 (move decimal three places left):
(1b) Enter “/cms Size” (above left) corresponding to the number of hard disks and disk size:
(1a)
(1b)
3.Compare the figures in (1a) and (1b) of the table. They should be approximately equal. The two will not correspond exactly, but they should be within about 10% of the /cms size figure. A major discrepancy between the disk space you should have and the space recognized by your Solstice DiskSuite software usually indicates a connectivity problem. You can check connectivity by checking the output of a metastat command to see that all the disks are recognized. For example:
*Solstice DiskSuite is a trademark of Sun Microsystems, Inc.