Lucent Technologies 585-210-940 manual Troubleshooting

Models: 585-210-940

1 106
Download 106 pages 54.9 Kb
Page 102
Image 102
Manual background

Troubleshooting

CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems

Error messages

96

 

 

Error Messages (Continued)

Message:

Explanation:

Response:

Usage: olds -mirrored -check_disks

-mirrored -mk_files-metadbs-cleanup -mirrored -setup [disk name]

You have mistyped a command.

Retry the command. See Chapter 3 for information about olds command syntax.

Message:

Explanation:

Warning: inode blocks/cyl group (230 >= data blocks (135) in lost cylinder group. This implies 2160 sector(s) cannot be allocated.

Some sectors will not be used by the filesystem. This is just a warning; the filesystem should be fine.

Message:

Explanation:

Response:

Warning: script does not support this

configuration, configure manually

The olds script is supported only with the hardware described in Chapter 1.

Verify that you have appropriate hardware. If you need extra disks for purposes other than mirroring CMS, you may attach them after disk mirroring has been installed and has been verified to be running correctly.

Message:

Response:

x25netd: failed to open

driver /dev/hihx (Bad file number [n] ) Enter the following command:

/cms/toolsbin/lnSBusdev

Message:

Explanation:

Response:

You must be root in order to run this command.

You are not logged in as the root user, but you must be in order to run the command.

Log in as root and retry the command.

Message:

Response:

You need to have at least one disk setup,

before attaching one.

Install and configure Solstice DiskSuite before attempting this task.

Page 102
Image 102
Lucent Technologies 585-210-940 manual Troubleshooting