Viewing diagnostic information

Table 3-1. Fields in the DSLPipe status window (Continued)

Fields

 

Description

 

 

 

V.35

ch Tx CRC

Shows either Enable or Disable. The default is Enable.

 

 

This means that the CRC is appended to the end of the frame

 

 

when data is sent over the V.35 line.

V.35

ch RxC

Indicates Norm (Normal) or Rev (Reverse). The default is

Polarity

Norm.This means that data will be sampled at the rising edge

 

 

of the clock.

V.35

ch TxC

Indicates Norm (Normal) or Rev (Reverse). The default is

Polarity

Norm.This means that data will be shifted out of the buffer at

 

 

the falling edge of the clock.

 

 

 

Viewing diagnostic information

After you set up the communications software and the DSLPipe unit’s configuration menu appears (see Figure 3-1), you can press 4 to enter debug mode and view diagnostic information. When you press 4, the following window appears:

SDSL V.35 DSU

Debug Mode

0.Return to Main Menu

1.Check HDLC Registers

2.Print Rx Data

Figure 3-2. Debug Mode window

At the Select Function Items prompt, press 1 to display the HDLC registers. Table 3-2 describes the fields that display in the list that appears.

DSLPipe DSU (SDSL) User’s Guide