Setting up the DSLPipe DSU

Setting the data transmission rate

To set the DSLPipe DSU data transmission rate, use a pen to move the DIP switches.Table 2-1 shows the DIP switch settings for each rate. Move the DIP switch down to turn the switch on. Move a switch up to turn it off.

Table 2-1. Data transmission settings

Rate

DIP Switch 1

DIP Switch 2

DIP Switch 3

 

 

 

 

144 Kbps

ON

ON

ON

 

 

 

 

272 Kbps

ON

ON

OFF

 

 

 

 

400 Kbps

ON

OFF

ON

 

 

 

 

528 Kbps

ON

OFF

OFF

 

 

 

 

784 Kbps

OFF

ON

ON

 

 

 

 

1168 Kbps

OFF

ON

OFF

 

 

 

 

1552 Kbps

OFF

OFF

ON

 

 

 

 

2320 Kbps

OFF

OFF

OFF

 

 

 

 

Configuring the unit as either CPE or COE

If you want the DSLPipe DSU to function as a CPE, leave the fourth DIP switch in the up (off) position. If you want the unit to function as a COE, move the fourth DIP switch down.

Note: JP3 and JP4 must be installed for Dip Switch 4 to be functional.

DSLPipe DSU (SDSL) User’s Guide

2-3

Page 17
Image 17
Lucent Technologies 7820-0657-001 manual Setting the data transmission rate