Lucent Technologies Release 4.0 manual DEFINITY AUDIX System Release, 3.DCP Mode 2 Connection

Models: Release 4.0

1 72
Download 72 pages 3.89 Kb
Page 22
Image 22
Figure 2-3. DCP Mode 2 Connection

DEFINITY AUDIX System Release 4.0

Issue 1

System Description Pocket Reference 585-300-214

May 1999

 

 

Design and Operation

 

Hard Disk Drive

2-6

 

 

In a DCP Mode 2 connection, the DEFINITY AUDIX system connects to a DCP port on a TN754 circuit pack. It then connects to an analog port in the switch’s analog trunk group via a data module and a modem.

Customers can use this connection with any DEFINITY or System 75 switch release. Figure 2-3 shows this connection

 

DEFINITY

 

 

 

system

 

 

 

DEFINITY

 

 

 

AUDIX

 

 

 

system

 

 

 

 

Data module

 

 

Digital line

DCP

 

 

circuit

 

 

 

pack

M7U null

 

 

 

Central

 

 

modem cable

Office

 

 

Analog

trunk

Analog

Analog

T/R

 

trunk

port

 

 

 

 

Modem

 

cydxsl14 KLC 012299

 

Figure 2-3. DCP Mode 2 Connection

Other DCP Mode 2 connections may be available for switch releases earlier than 7.1. See DEFINITY AUDIX System — Digital Networking , 585-300-534, for more information about DCP Mode 2 connections in these switches.