Troubleshooting – Honeywell VS8421

360 DVS Series Direct Vent Fireplaces

Troubleshooting – Honeywell VS8421

START

Gas Supply On

YES

Pilot Lights With Piezo Ignitor

YES

PILOT STAYS LIT

YES

PILOT LIGHTS MAIN BURNER

YES

SYSTEM OK

NO

NO

NO

NO

CHECK

Supply Line Hooked Up

Shutoff Valve Open

Lockout Has Engaged. Wait 60 Seconds And Try Again.

For Spark At Electrode While Depressing Piezo

1/8" Gap To Pilot Hood Needed.

All Wiring Connections

Replace Piezo Ignitor

For Air In The Lines

Thermopile Needs A Min. 325mv. Adjust Pilot Flame Height.

All Wiring Connections

Replace Thermopile

Thermocouple Needs A Min. Of 14mv

Valve Is Turned On

Wall Switch Is Not Turned On. Watch For Grounded Wires!

Thermopile Needs A Min. 325mv.

Plugged Burner Orifice

Defective Valve. Turn To Pilot, Meter Should Read Greater Than 100mv. If Not, Replace.