360DVS Series Direct Vent Fireplaces
Optional Accessories
Fan Kits
FK24 Fan Assembly
This auxiliary fan system increases the efficiency of the circulation of the heated air.
The FK24 fan kit allows variable speed control of the circulation fan and also incorporates a heat sensor in the circuit.
Specifications
115 Volt / 60Hz / 56 Watts
Maintenance
The fan itself does not require regular maintenance, however periodic cleaning of the fan and the surround- ing area is required.
Check the area under the control door (lower louvre as- sembly) and in front of the fan and wipe or vacuum this area at least once a month during the operating season.
Installation
The fan assembly and other components are supplied fully wired, eliminating the need for a licensed electri- cian to carry out the installation.
If hard wiring the fan in using Method B (following) we strongly recommend the use of a licensed electrician.
1.Open the lower louvre assembly. Maneuver the fan and bracket assembly around the gas valve and lines to locate the unit onto the screw studs on the back of the fireplace.
2.Install the thermal sensor under the bottom of the firebox, locating it over the two (2) 10 mm studs, and secure it with nuts.
3.Locate the fan speed control unit. This can be fit- ted behind the lower louvre assembly as in Figure 51, or located remotely in a conveniently located wall mounted electrical box. Remote location of the speed control will require suitable extension of the component wiring.
4.The power supply may be connected in two ways:
Method A
Route the 6’ lead fitted to the unit to a conveniently located wall socket.
Method B
The
10006326
FK12
This auxiliary fan system increases the efficiency of the circulation of the heating air.
The FK12 Fan Assembly is a fixed speed fan system and does not allow for variable speed control. It does not use the speed control unit or the heat sensor in- cluded with the FK24 Kit.
Specifications
115 Volts / 60 Hz / 56 Watts.
Maintenance
The fan itself does not require regular maintenance; however, periodic cleaning of the fan and the surround- ing area is required.
Check the area under the control door (lower louvre assembly), and in front of the fan. Wipe or vacuum this area at least once a month during the operating season.
Installation
The fan assembly is supplied fully wired eliminating the need for a licensed electrician to carry out the installa- tion.
1.Open the lower Louvre assembly. Maneuver the fan and bracket assembly around the gas valve and lines to locate the unit against the back wall of the appliance, resting on the base.
2.With the protective cover removed from the
3.Power to the fan can be supplied by plugging the supplied lead into a
FK24 Fan | |
| Electrical |
| Inlet Hole |
Fan Speed | |
Control Box | |
| Gas |
| Inlet |
| Hole |
| Heat |
| Sensor |
FP1448 | Electrical Box |
| |
Fig. 51 | Fan installation. |
| 39 |