Majestic Appliances 360DVS2 Maintenance, Cleaning the Standing Pilot Control System, Brass Trim

Models: 360DVS3 360DVS2 360DVSR 360DVSL

1 44
Download 44 pages 34.52 Kb
Page 35
Image 35
Maintenance

360DVS Series Direct Vent Fireplaces

Maintenance

Burner and Burner Compartment

It is important to keep the burner and the burner com- partment clean. At least once per year remove the logs and lava rock/ember material. Vacuum and wipe out the burner compartment. Remove and refit the logs per the instructions in this manual.

Always handle the logs with care as they are fragile and may also be hot if the fire-

Burner and Burner Compartment place has been in use. FK24/FK12 Fan Assembly

The fan unit requires periodic cleaning. At least once per month in the operating season, open the lower lou- vre panels and wipe or vacuum the area around the fan to remove any build up of dust or lint.

Brass Trim

Clean the brass trim pieces using a soft cloth lightly dampened with lemon oil. Do not use water or house- hold cleaners on any brass components.

Cleaning the

Standing Pilot Control System

The burner and control system consists of:

burner tube

gas orifice

pilot assembly

thermopile

millivolt gas valve

 

 

Most of these components may require only an occa- sional checkup and cleaning and some may require ad- justment. If repair is necessary, it should be performed by a qualified technician.

1.Turn off pilot light at gas valve side.

2.Let fireplace cool if it has been running.

3.Remove window frame assembly. (Refer to Window Frame Assembly Removal section)

4.Remove logs.

5.Vacuum burner compartment especially around orifice primary air openings.

6.Visually inspect pilot. Brush or blow away any dust or lint accumulation.

7.Reinstall logs.

8.Ignite pilot; refer to Lighting Instructions.

9.Reinstall window frame assembly.

To obtain proper operation, it is imperative that the pilot and burner’s flame characteristics are steady, not lifting or floating.

Typically, the top 3/8 – 1/2” (10 – 13 mm) of the thermo- pile should be engulfed in the pilot flame. (Page 26, Fig. 46)

To adjust pilot burner (to be done by a qualified service technician):

1.Remove pilot adjustment cap.

2.Adjust pilot screw to provide properly sized flame.

3.Replace pilot adjustment cap.

The primary air shutter is set at factory and should be adjusted, if necessary, only by a qualified service tech- nician.

Cleaning Electronic Ignition System

The Electronic Ignition burner/control system consists of:

main burner

gas orifice

pilot burner

24VAC valve with transformer

The process for taking care of Electronic Ignition units is identical to that for taking care of Standing Pilot models.

10006326

35

Page 35
Image 35
Majestic Appliances 360DVS2 Maintenance, Cleaning the Standing Pilot Control System, Cleaning Electronic Ignition System