Majestic Appliances 360DVS2, 360DVSR Troubleshooting the Gas Control System, Start, 10006326

Models: 360DVS3 360DVS2 360DVSR 360DVSL

1 44
Download 44 pages 34.52 Kb
Page 31
Image 31
START

360DVS Series Direct Vent Fireplaces

Troubleshooting the Gas Control System

SIT 822 Valve with a Honeywell Electronic Igniter

START

NOTE: Remove glass before servicing.

 

NOTE: Remove glass before servicing. TURN GAS SUPPLY OFF. NO

Manual background TURN ON/OFF SWITCH

TO CALL FOR HEAT.

POWER TO MODULE?

(24V NORMAL)

YESManual background

SPARK ACROSS NO IGNITOR SENSOR GAP?

YES

CHECK: Manual background LINE VOLTAGE (120VAC).

Manual background LOW VOLTAGE TRANSFORMER (19.5 MINIMUM VAC).

Manual background ON/OFF SWITCH. Manual background WIRING CONNECTIONS.

UNPLUG IGNITION LEAD

AND CHECK SPARK

AT MODULE

(24VAC NORMAL).

NO

 

SPARK OK?

REPLACE MODULE.

 

YES Manual background

Manual background CHECK IGNITION CABLE GROUND WIRING, CERAMIC INSULATOR, AND GAP. CORRECT AS NECESSARY.

Manual background CHECK BOOT OF IGNITION CABLE FOR SIGNS OF MELTING OR BUCKLING. TAKE PROTECTIVE ACTION TO SHIELD CABLE AND BOOT FROM EXCESSIVE TEMPERATURES.

TURN GAS ON.

NO

CHECK THAT ALL MANUAL GAS VALVES ARE OPEN, SUPPLY TUBING

 

 

 

PILOT BURNER LIGHTS?

 

AND PRESSURES ARE GOOD, AND PILOT BURNER ORIFICE IS NOT

YES

 

 

BLOCKED.

 

 

 

 

CHECK ELECTRICAL CONNECTIONS BETWEEN MODULE AND PILOT

 

 

 

OPERATOR ON GAS CONTROL.

 

 

 

CHECK FOR 24VAC ACROSS PV-MVPV TERMINALS ON MODULE. IF

 

 

 

VOLTAGE IS OKAY, REPLACE GAS CONTROL IF NOT, REPLACE MODULE.

 

 

 

 

SPARK STOPS WHEN

NO

NOTE: IF S8600B GOES INTO LOCKOUT, RESET SYSTEM.

 

 

PILOT IS LIT?

 

 

CHECK CONTINUITY OF IGNITION CABLE AND GROUND WIRE.

YES

 

 

 

CLEAN FLAME ROD.

 

 

 

 

CHECK ELECTRICAL CONNECTIONS BETWEEN FLAME ROD & MODULE.

 

 

 

 

CHECK FOR CRACKED CERAMIC FLAME ROD INSULATOR.

 

 

 

 

CHECK THAT PILOT FLAME COVERS FLAME ROD AND IS STEADY BLUE.

 

 

 

 

ADJUST PILOT FLAME.

 

 

 

 

IF PROBLEM PERSISTS, REPLACE MODULE.

 

 

 

 

 

NO

MAIN BURNER LIGHTS?

YES

SYSTEM RUNS UNTIL NO ON/OFF SWITCH IS IN

"OFF" POSITION? YES

TROUBLESHOOTING

ENDS.

CHECK FOR 24VAC ACROSS MV-MVPV TERMINALS. IF NO VOLTAGE, REPLACE MODULE.

CHECK ELECTRICAL CONNECTIONS BETWEEN MODULE AND GAS CONTROL. IF OKAY, REPLACE GAS CONTROL OR GAS CONTROL OPERATOR.

NOTE: IF S8600B GOES INTO LOCKOUT, RESET SYSTEM.

Manual background CHECK FOR CONTINUITY OF IGNITION CABLE AND GROUND WIRE. NOTE: IF GROUND IS POOR OR ERRATIC, SHUTDOWN MAY OCCUR OCCASIONALLY EVEN THOUGH OPERATION IS NORMAL AT THE TIME OF CHECKOUT.

Manual background CHECK THAT THE PILOT FLAME COVERS FLAME ROD AND IS STEADY AND BLUE.

Manual background IF CHECKS ARE OKAY, REPLACE MODULE.

10006326

31

Page 31
Image 31
Majestic Appliances 360DVS2 Troubleshooting the Gas Control System, 360DVS Series Direct Vent Fireplaces, Start, 10006326