STOPPING THE GENERATOR

(a)Turn off the power switch of the electric equipment and unplug the cord from receptacle of the generator.

(b)Turn the AC circuit breaker to the "OFF" position.

(c)Allow the engine about 3 minutes to cool down at no-load before stopping.

(d)Recoil starter model

Turn the engine switch to the position "OFF".

Electric starter model

Turn the key switch to the STOP position.

(e) Close the fuel valve.

OFF

STOP

STOP

ON

OFF

ON

OFF

RUN

RUN

 

ST

START

ART

OIL SENSOR

(a)The oil sensor detects the fall in oil level in the crankcase and automati- cally stops the engine when the oil level falls below a predetermined level.

(b)When engine has stopped automatically, switch off generator's AC circuit breaker, and check the oil level.

Refill engine oil to the upper level as instructed on page 7 and restart the engine.

(c)If the engine does not start by usual starting procedures, check the oil level.

CLOSE

CLOSE

OPEN

Oil sensor

20

Page 25
Image 25
Makita EG781AE, EG711A, EG301A Stopping the Generator, OIL Sensor, [Recoil starter model], [Electric starter model], - 20-