FULL POWER SWITCH (Except EG301A)

Select the voltage using the FULL POWER SWITCH in accordance with the electrical appliance.

Refer to TABLE 2.

CAUTION

Change the FULL POWER SWITCH after turning the AC circuit breaker to "OFF".

120V

120V 240V

ENGLISH

Switch position

Lower Voltage Receptacle

Higher Voltage Receptacle

120V

Activated full rated output

N.A

120/240V

Activated half of rated output

Activated full rated output

TABLE 2

(1) CHECKING THE OPERATION

Overloaded ?

Please make it sure that the generator is not overload.

NOTE :

Most induction loads such as electric motors require three to five times more wattage than their ratings during starting.

(2) STOPPING THE ENGINE

Turn off the switch of load.

Switch off generator's AC breaker.

Disconnect tool or appliance.

Turn the STOP SWITCH to the position "O" (OFF).

NOTE :

Allow the engine about 3 minutes to cool down at no-load before stopping.