Ampere Receptacle

AC plug

Description

 

 

NEMA

NEMA

GFCI (Ground Fault

 

up to 20A

Circuit Interrupter)

 

5-20R

5-20P

Receptacle, duplex

 

 

 

 

 

 

(REC1)

 

up to 30A

NEMA

NEMA

Locking Receptacle

 

L5-30R

L5-30P

(REC3)

 

 

 

up to 30A

NEMA

NEMA

Locking Receptacle

 

L14-30R

L14-30P

(REC4)

 

 

TABLE 1

WARNING

 

To take power out from the TWIST

TWIST

LOCK RECEPTACLE, insert the

 

plug into the receptacle, and turn

 

it clockwise to the lock position.

 

Be sure to ground the generator if the connected electrical device Is

grounded.

NOTE :

When the AC circuit breaker turns off during operation, the generator is over loaded or the appliance is defective. Stop the generator immediately, check the appliance and / or generator for overloading or detect and have repaired as necessary by Makita factory or authorized service center.

CAUTION

The duplex 120V receptacle is protected by a GFCI (Ground Fault Circuit Interrupter). GFCI shuts off the output current from the duplex 120V receptacle when a ground fault occurs in the generator or the appliance. Please note that other receptacles are not protected by GFCI.