Makita EG511AE, EG301A, EG711AE, EG381AE, EG781AE manual Preparation for Storage, - 30-

Models: EG711AE EG381A EG301A EG781AE EG511A EG781A EG511AE EG711A EG381AE

1 42
Download 42 pages 35 Kb
Page 35
Image 35

10. PREPARATION FOR STORAGE

The following procedures should be followed prior to storage of your generator for periods of 6 months or longer.

Drain fuel from fuel tank carefully by disconnecting the fuel line. Gasoline left in the fuel tank will eventually deteriorate making engine- starting difficult.

Remove the carburetor float chamber and also drain the carburetor.

Change engine oil.

Check for loose bolts and screws, tighten them if necessary.

Drain screw

Clean generator thoroughly with oiled cloth. Spray with preservative if available. NEVER USE WATER TO CLEAN GENERATOR !

Pull starter handle until resistance is felt, leaving handle in that position.

Store generator in a well ventilated, low humidity area.

30

Page 35
Image 35
Makita EG511AE, EG301A, EG711AE, EG381AE, EG781AE manual Preparation for Storage, - 30-