CHECKING COMPONENT PARTS

Check following items before starting engine:

Fuel leakage from fuel hose, etc.

Bolts and nuts for looseness.

Components for damage or breakage.

Generator not resting on or against any adjacent wiring.

CHECK GENERATOR SURROUNDINGS

WARNING

Make sure you review each warning in order to prevent fire hazard.

Keep area clear of in flammables or other hazardous materials.

Keep generator at least 3 feet (1 meter) away from buildings or other structures.

Only operate generator in a dry, well ventilated area.

Keep exhaust pipe clear of foreign objects.

Keep generator away from open flame. No smoking!

Keep generator on a stable and level surface.

Do not block generator air vents with paper or other material.

ENGLISH

BATTERY INSTALLATION (Electric Starter Model)

Recommended Battery

Type

; Lead-acid battery

 

 

Capacity (Ah/5hr) ; 12V-21AH or more

 

 

Size

; Less than 185(L) x 125(W) x 160(H) mm

Earth Cable(BLACK)

Setting Plate

Bolt

Protection Plate

 

 

 

Nut

 

 

 

 

 

Battery Frame #1

Bolt

Starter Cable(RED)

 

 

 

 

Bolt

Nut

 

 

 

 

 

 

 

Setting Bolt

 

 

 

 

 

 

 

 

 

Bolt

 

Nut

 

 

 

 

 

Bolt

 

Battery Plate

Battery Frame #2

 

 

 

 

9

 

 

Page 14
Image 14
Makita EG511A, EG301A, EG711AE, EG381AE, EG781AE manual Checking Component Parts, Check Generator Surroundings, - 9-