5. OPERATING PROCEDURES

STARTING THE GENERATOR

CAUTION

Check the oil level before each operations as outlined by the article

"CHECK ENGINE OIL"

ENGLISH

(a)Turn the Engine switch to the position "ON".

(b)Turn the AC circuit breaker to the position "OFF".

(c)Open the fuel valve.

(d)Set choke lever to close if the engine is cold.

ON

OFF

ON

OFF

OFF

 

CLOSE

CLOSE

 

 

OPEN

Choke lever

CLOSE

OPEN

11

Page 16
Image 16