PRESETTING
Presseting Parameters
Presetting parameters, the unit can be tuned to be most suitable for each user.
Presettable Parameters
•Bit rate (MPEG or PCM) assigned to each of SP/LP/ MP mode.
•Threshold sound level to detect silence in silent skip mode.
•Threshold time to detect silence in silent skip mode.
•Battery Type
•File format of recorded track.
•ID1 (6 digits)
•ID2 (6 digits)
•ID3 (6 digits)
Parameter | Selectable Setting for | Default |
| the Parameter | Setting |
|
|
|
Bit rate of SP | 768, 192, 128, 96 kbps | 192 kbps |
|
|
|
Bit rate of MP | 192, 128, 96, 48 kbps | 96 kbps |
|
|
|
Bit rate of LP | 128, 96, 48,32 kbps | 64 kbps |
|
|
|
Sound level for silent skip | ||
|
|
|
Silent time for silent skip | 1 to 5 second, 1 second step | 3 seconds |
|
|
|
Battery type | Alkaline, | Alkaline |
|
|
|
File format | WAVE, LPEG2, BWF | WAVE |
|
|
|
ID1,2,3 | 000000 to 999999 | 000000 |
|
|
|
Note
For example, ID1 for ID of the broadcasting station, ID2 for the department code, ID3 for the budge number of the reporter. ID1, ID2, and ID3 are recorded in the "Broadcast Audio Extension" chunk of BWF as follows.
ID1: Description (the first 6 characters in 256 columns)
ID2: Originator (the first 6 characters in 32 columns)
ID3: Originator Reference (the first 6 characters in 32 columns)
Preset Operation
AUTO MARK
PRESET
1 / 4 ¢ / ¡
PLAY / PAUSE
(6)
STOP (7)
•From standby (power off) status, turn power on while pressing MARK SELECT key. The unit enters preset mode.
•Using 1/4 key or ¢/¡ key, select which parameter to be set
•Parameter menu is displayed blinking cyclically as follows;
Bit rate for SP → | Bit rate for MP → | Bit rate for LP → | |
Sound level for silent skip → | Silent time for silent skip | ||
Battery type → | File format → | ID1 | ID2 ID3 |
1.While blinking, press PLAY/PAUSE key. Then the blinking parameter is selected as a parameter to be changed, and blinking of parameter stops to be stable on. Instead, settings for the parameter start to blink.
2.Using 1/4 key or ¢/¡ key, display the selectable settings.
3.Press PLAY/PAUSE key, displayed setting is assigned to the parameter .
4.After setting the value for the parameter, you can again select the parameter to be set using 1/4 key or ¢/¡ key. The parameter menu blinks.
(Return to item 1).
5.Pressing MARK/SELECT key, updated parameters are registered and become effective. The unit enters stop status.
6.Instead, pressing STOP key, update is not done. The preset values stay as it they were before entering preset menu. The unit enters stop status.
Nesting of Parameter Presetting Menu
Standby Status (Power off) |
| ||||
|
|
|
|
| |
|
|
|
|
| |
MARK SELECT |
| Stop Status |
| ||
|
|
|
| ||
+POWER |
|
| DISPLAY | ||
|
| ||||
|
|
| |||
|
|
|
| 1/ 4, ¢/ ¡ | |
|
|
|
| ||
Parameter Selection Menu | |||||
| |||||
|
|
|
|
| |
PLAY / PAUSE |
|
| PLAY / PAUSE | ||
|
|
|
| 1/ 4, ¢/ ¡ | |
|
|
|
| ||
Setting assign menu | |||||
| |||||
|
|
|
|
|
Parameter Selection
Setting Selection
24