DS5001FP
26 of 26
REVISION HISTORY
The following represent the key differences between 112795 and 073096 version of the DS5001FP data
sheet. Please review this summary carefully.
1) Change VCC02 specification from VLI - 0.5 to VLI - 0.65 (PCN F62501).
2) Update mechanical specifications.
The following represent the key differences between 073096 and 111996 version of the DS5001FP data
sheet. Please review this summary carefully.
1) Change VCC01 from VCC - 0.3 to VCC - 0.35.
The following represent the key differences between 111996 and 061297 version of the DS5001FP data
sheet. Please review this summary carefully.
1) PF signal moved from VOL2 test specification to VOL1. PCN No. (D72502)
2) AC characteristics for battery-backed SDI pulse specification added.
The following represent the key differences between 061297 and 051099 version of the DS5001FP data
sheet. Please review this summary carefully.
1) Reduced absolute maximum voltage to VCC + 0.5V.
2) Added note clarifying storage temperature specification is for non-battery-backed state.
3) Changed RRE min (industrial temp range) from 40kW to 30kW.
4) Changed VPFW max (industrial temp range) from 4.5V to 4.6V.
5) Added industrial specification for ILI.
6) Reduced tCE1HOV and tCEHDV from 10ns to 0ns.
The following represent the key differences between 051099 and 052499 version of the DS5001FP data
sheet. Please review this summary carefully.
1) Minor markups and ready for approval.