DS5001FP
17 of 26
AC CHARACTE RISTICS (continued)
POWER CYCLE TIME (TA = 0°C to +70°C; VCC = 5V ±10%)
# PARAMETER SYMBOL MIN MAX UNITS
32 Slew Rate from VCCMIN to VLI tF130 µs
33 Crystal Startup Time tCSU (Note 9)
34 Power-On Reset Delay tPOR 21,504 tCLK
POWER CYCLE TIMING