Table 4-1 S - Registers

 

Register Function

Range/units Default

S0

Auto-answer Ring

0-255/rings

0

S1

Ring counter

0-255/rings

0

S2

Escape code character

0-127/ASCII

43

S3

Carriage return character

0-127/ASCII

13

S4

Line feed character

0-127/ASCII

10

S5

Backspace character

0-32, 127/ASCII

8

S6

Dial tone wait time

0-255/seconds

2

S7

Remote carrier wait time

1-255/seconds

60

S8

Comma pause time

0-255/seconds

2

S9

Carrier detect time

0-255/0.1 second

6

S10

Carrier loss time

0-255/0.1 second

7

S11

Touch-tone dialing speed

50-255/0.001 second

70

S12

Esc. character detect time

0-255/0.02 second

50

S14

Echo, response, dialing,

Bit-mapped

 

 

originate/answer

 

 

S16

Modem test options

Bit-mapped

 

S18

Modem test timer

0-255/seconds

0

S21

DTR, DCD, DSR, and

Bit-mapped

 

 

Long Space Disconnect

 

 

S22

Speaker and response

Bit-mapped

 

S23

RDL, DTE data rate,

Bit-mapped

 

 

parity,and guard tone

 

 

S25

DTR delay

0-100/seconds

5

S27

Async operation, CCITT/

Bit-mapped

 

 

Bell mode

 

 

S30

Disconnect timer

0-255/seconds

0

S31

Automode,Trellis coding,

Bit-mapped

 

 

calling tone, auto-retrain,

 

 

 

rate renegotiation

 

 

S33

Sleep mode time

0-90/seconds

10

 

 

 

 

Section Five - Result Codes

BASIC RESPONSE CODES

OK

0

CONNECT

1

RING

2

NO CARRIER

3

ERROR

4

CONNECT 1200

5

NO DIALTONE

6

BUSY

7

NO ANSWER

8

CONNECT 1200/75 22

CONNECT 75/1200 23

CONNECT 2400

10

CONNECT 4800

11

CONNECT 7200

24

CONNECT 9600

12

CONNECT 12000

25

CONNECT 14400

13

CONNECT 16800

59

CONNECT 19200

14

CONNECT 21600

61

CONNECT 24000

62

CONNECT 26400

63

CONNECT 28800

64

CONNECT 31200

65

14

Page 16