INTERFACE COMMANDS

Set Feature Commands

Set Features Mode

Enables or disables features supported by the drive. When the drive receives this command it:

1.Sets BSY,

2.Checks the contents of the Features register,

3.Clears BSY and

4.Generates an interrupt.

If the value of the register is not a feature supported by the drive, the command is aborted. The acceptable values in the Features register are defined as follows:

VALUE

DESCRIPTION

02h*

Enabled write cache

 

 

03h

Set transfer mode based on value in Sector Count register

44h

Length of data appended on Read Long/Write Long commands specified in the

 

Identify Device information

 

 

55h

Disable read look-ahead feature

66h*

Disable reverting to power-on defaults

 

 

82h

Disable write cache

AAh*

Enable read look-ahead feature

 

 

BBh*

4 bytes of Maxtor specific data appended on Read Long/Write Long commands

CCh

Enable reverting to power-on defaults

 

 

* Enabled at power up by default.

7 – 6

Page 54
Image 54
Maxtor 91024D4, 90750D3, 91280D5, 91536D6, 91792D7, 92048D8 manual Set Feature Commands, Set Features Mode