Troubleshooting Procedures

!WARNING

To avoid risk of electrical shock, personal injury or death, disconnect power to unit before servicing, unless testing requires power.

Test or Display

Fast

Time-

Down / Advance to Next Step

Quick

Service

Cycle

Hold Quick

Service Cycle

Step

LED/Switch

Test

Press LED to

Press LED to

Start

Cancel

Press

Press Power

Temperature

Off

to start test.

 

Press

 

Temperature

 

during cycle to

 

advance.

 

Press

Press Off (also

Temperature

exits Service

and Soil Level

Mode)

Press

Press

Rinse&Spin

Rinse&Spin

and Spin Only

and Spin Only

together

to resume

Press Delay for

Press Off twice

3 seconds (then

after starting

individual

test

buttons to test)

 

Rotate Cycle

 

Selector

 

clockwise, the

 

LED’s around it

 

will be toggled.

 

Test or Display

All Diagnostic Codes

Cycle Count No. for Diagnostic Code

Clear All

Diagnostic

Codes

Display

Software

Version

Cycle Count

Press LED to

Press LED to

Start

Cancel

Rotate Cycle

N/A

Selector either

 

direction

 

Press and hold

Release Rotary

Rotary

Selector

Selector, while

(returns to

diagnostic code

diagnostic code

is displayed

display)

Press Delay

 

and Chime

 

together while

 

displaying

 

diagnostic

 

codes

 

Press Soil

Press Soil

Level. Press 2

Level a 3rd time

times for

 

displays with

 

only 2 character

 

positions.

 

Press Chime

 

Rotate

counterclockwis

e, the7-

segment LED’s

toggle. Press

Rotary Cycle

Selector, all of

the LED’s

around the

Rotary Cycle

Quick Spin Test

While in Service Mode, press Delay and Rinse&Spin keys to start a Quick Spin Test. Quick Spin test steps are as follows:

Start spinning and after reaching a maximum spin speed.

stay at maximum spin speed for 2 minutes and stop Quick Spin Test.

Hold Quick Spin Step

IN

Board

Input

Test

Selector will be

 

toggled.

 

Press Spin

Press Spin

Only

Only

If the Rotary Selector key is pressed during the Quick Spin test, the machine will hold at the next highest index speed for up to 10 minutes. At the end of 10 minutes, the machine will resume and finish the Quick Spin test. To cancel the Hold and allow the

Board

Output

Test /

System Check

Diagnostic Code Display (Initial)

Press Spin

Press Off

Speed

 

Press Rinse&

Press

Spin – displays

Rinse&Spin

“d”

again

Spin Test to continue, press the Delay and Rinse&Spin keys.

14

16025909 Rev. 0

©2005 Maytag Services