Disassembly Procedures

!WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to unit before servicing.

Water Valve Removal

1.Disconnect power supply to unit.

2.Remove Top Cover.

3.Remove two screws each hot and 3 valve combo cold valve.

Combo Cold Valve

Hot Valve

4. Remove hose clamps and hoses.

NOTE: The hose circuitry is marked on the Dispenser top.

Dispenser Removal

1.Disconnect power supply to unit.

2.Depress the release tab and slide drawer from washer.

3.Remove Top Cover.

4.Remove clamps and hoses from dispenser.

Pre

Main

Bleach

Main

Wash

Hot

 

Cold

NOTE: The hose circuitry is marked on the Dispenser top.

5.Remove attachment screws and lift dipenser to expose fill hose.

28

16025909 Rev. 0

©2005 Maytag Services

Page 28
Image 28
Maytag MAH9700AW* manual Water Valve Removal