FIG 6 - Removal of Fan Safety Guard

Bottom plate

Lug

Lug

Lug

To remove safety guard, turn counterclockwise until lugs release.

To fit, align 4 lugs on

Rotate clockwise to fit

and tighten

fan housing with 4 slots

 

on safety guard, then turn

clockwise until tight.

 

 

Slot

Lug

Slot

 

Slot

 

Rotate counterclockwise

Slot

to remove

The casing of your Mega-Catch™ Mosquito Trap is made from polypropylene, which is extremely strong and durable. Its appearance is best maintained by a plastic protector of the type used on plastic car fenders. Do not use wax.

In order to prolong the life of your Mega-Catch™ Mosquito Trap store it and the Mega-Catch™ Stand in a dry place when not in operation. Your Mega-Catch™ Mosquito Trap should be serviced at the end of each season (see Page 17 - Maintenance and Repair of Your Trap section).

Replacement of U.V. Blub

The U.V. Bulb is a consumable item and replacements can be obtained from your Authorized Distributor. To install a new U.V. Bulb refer to Page 17 - Maintenance and Repair of Your Trap section.