Melitta 2954076 manual unit, Temperature regulator, Control panel, 5.1.4.1, Brief description

Models: 2954076

1 96
Download 96 pages 50.62 Kb
Page 32
Image 32
5.1.4

OPERATION

5.1.4

Temperature regulator

 

 

unit

 

Control panel

E

5.1.4.1

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

7

1Digit light spot "setting mode"

2Above: "Compressor" symbol,

below: digit light spot

3Rocker switch

4ENTER function

5UP function

6DOWN function

7Display (3 digits)

5.1.4.2Brief description

The temperature regulator unit controls the compressor for the installed EF milk cooler. During operation, the display shows the ap- proximate actual temperature of the milk in the milk container. The actual milk temper- ature is taken from the plate on which the milk container stands.

NOTE

Pre-cooled milk that is no hotter than 1 - 5 °C should be used. See also section «5.5.4 Refill milk, 5 - 22».

The temperature indicator on the display shows the ap- proximate actual tempera- ture of the milk in the milk container, not the internal temperature of the installed EF milk cooler.

5.1.4.3Cooling operation

The digit light spot beneath the "Compres- sor" symbol is illuminated as long as the compressor is in operation.

NOTE

The compressor is switched on by the temperature regu- lator unit when the actual milk temperature is 2 °C above the setting for the de- sired milk temperature.

© Cafina / Melitta

5 - 2

OI c5 eng V9 / 18.08.2006

Page 32
Image 32
Melitta 2954076 manual unit, Temperature regulator, Control panel, 5.1.4.1, Brief description, Cooling operation