16.2Drive Belt Tension/Replacement
B
C
AA
After loosening the six nuts (A) the motor mounting plate can be pushed downward to tension the main drive belt.
Loosen screws (B and C) to move the transmission base plate for tensioning the thicknesser drive belt.
Play of main drive belt at 5 Nm tension approx. 20 mm
Play of thicknesser drive belt at 5 Nm approx. 20 mm.
16.3Servicing/Replacing the Recoil Lock
Damaged or worn
After removal of the two fastening screws the recoil lock assembly is removed from the machine.
New
16.4Checking Limit Switches and Motorbrake
Note: In case of a damaged limit switch lead the machine may start during testing. This test should therefore only be carried out by qualified service personel.
Swing the infeed table up to its upright position and cover the cutterblock by setting the fence assembly against the table.
When actuating the switch the ma- chine must not start.
Swing the outfeed table up to its upright position and cover the cutterblock by setting the fence assembly against the table.
The braking period (time to motor standstill) must be checked in at least monthly intervals. The braking period must not be more then 10 sec. If the motor needs more then 10 sec. to come to standstill, the motorbrake or the complete motor have to be replaced.