getting started (continued)
connecting the Pulsar EXB battery extension modules
(option)
ccheck that the button 3 "" on the front of Pulsar EX is in the released position;
ccheck that the battery switch 7 on Pulsar EX and the
ccheck that the cable 5 really is disconnected from the AC power or, in the case of cable connection, that the AC power really has been cut;
copen the cover 9 protecting the Pulsar EX and 33 on Pulsar EXB;
cplug the battery connecting cable 35 supplied with Pulsar EXB into the connectors 9 of Pulsar EX and 33 of Pulsar EXB (see figure 6);
cin the case of an installation containing 2 battery modules, connect the second cable 35 into the connectors 34 of the first module and 33 of the second module;
c the use of connectors 33 and 34 is | Figure 6 |
strictly limited to connection of 1 or 2 battery |
|
modules with Pulsar EX. |
|
Any other connection on these connectors is |
|
forbidden as it risks damaging the battery |
|
and voiding the warranty; |
|
crefer to the "operation" section for startup of Pulsar EX.
32 |
|
33 | 32 |
34 | 34 |
| 33 |
35 |
|
9 | 8 |
| 35 |
7
MGE UPS SYSTEMS | Pulsar EX: 51032306XT/BB | 31 |