Product: |
| (Driver version: 9.21) | ||
Type | : | Desktop |
|
|
Image sensor | : Color CCD (Reduced optical system) | |||
Operating method | : Document fixed Flat bed (FB), Automatic Document Feed | |||
|
| (ADF), Simultaneous | ||
|
| Long page scanning : Max 216mm x 3175mm1 | ||
Light source | : | Fluorescent tube (White) | ||
Basic resolution | : | 600dpi |
|
|
Output resolution | : 50 dpi to 600 dpi (at steps of 1dpi), 1200dpi | |||
Grayscale levels (internal) | : 10 bit 1024 levels | |||
Grayscale output | : | Enabled (8 bits) | ||
Halftone Patterns | : Dither matrix (can be downloaded), Error diffusion | |||
Color (24bit) output | : | Enabled |
|
|
Flat bed scanning speed | : | B/W : 1.7 sec or less (200 dpi, A4) | ||
|
| Color : 1.7 sec or less (150 dpi, A4) | ||
ADF scanning speed 2 | : | B/W |
|
|
|
| Single sided: 60 pages per minute (200 dpi, A4, 80g/m2) | ||
|
| Double sided: 60 pages per minute (200 dpi, A4, 80g/m2) | ||
|
| (=120 screens per minute) | ||
|
| Color |
|
|
|
| Single sided: 40 pages per minute (150 dpi, A4, 80g/m2) | ||
|
| Double sided: 40 pages per minute (150 dpi, A4, 80g/m2) | ||
|
| (=80 screens per minute) | ||
ADF paper chute capacity | : Maximum 50 sheets (A4, 80g/m2, High quality paper, normal | |||
|
| temperature and humidity) | ||
Document size | : | Minimum 53mm x 74 mm | ||
|
| Maximum 216mm x 355.6mm <ADF> | ||
|
| Maximum 216 mm x 297 mm <Flat Bed> | ||
Supported regular paper 3 | : A4, A5/A5 Landscape, A6/A6 Landscape, B5, | |||
|
| B6/B6 Landscape, Letter, Legal, US Executive, Name card | ||
Scanning area specification | : | Specified (one location) | ||
White level follower | : | Disabled |
|
|
1
2
3
If you specify a “long page” which is longer than 864mm, you must specify a resolution of 200dpi or less.
This speed is only specified for the scanner itself. The actual reading speed may vary depending on the system configuration.
Not all paper sizes can be used in all devices. For details, refer to the operator’s guide of the device. For other paper sizes, the customer settings can be used.