SECTION 2
INSTALLATION
UTILITY ROUGH-IN DIMENSIONS AND POSITIONING
FOR PS540-SERIES OVENS
WARNING
DO NOT USE CONDUIT OR GAS LINE FOR GROUND CONNECTION.
CAUTION
IT IS REQUIRED THAT THE OVEN BE PLACED UNDER A VENTILATION
5
ON 6
OFF
2 3
1
2 24" 610mm
6
ON
27"
686mm
HOOD FOR ADEQUATE AIR SUPPLY AND VENTILATION.
2
OFF
3
ELECTRIC AND GAS SUPPLY TO BE
PROVIDED BY CUSTOMER
ELECTRICAL SAFETY SWITCH
15 Amp circuit breaker / fused disconnect switch with lockout/tagout electrical shutoff for each oven. Wire each oven separately.
ELECTRICAL SPECIFICATIONS
DOMESTIC or EXPORT:
Do NOT use conduit for ground.
GAS RATING
Model PS540 is 110,000 BTU/hour, 116.0 mJ/h (27,720 kcal), 32.2 kW/hr.
MINIMUM GAS METER RATING
450 ft3/hour (12.6m3/h) for 1 or 2 ovens;
Add 180 cu. ft./hr (5.1 m3/h) for each additional oven.
Minimum rating does not take other gas appliances into consideration. Gas consumption varies at each site. Total BTU/hr (kcal/hr) must be calculated during high flame operation for each appliance to determine if the meter needs to be larger.
MINIMUM GAS PIPE SIZE
Natural: 2″ (51mm) ID for 1, 2, or 3 ovens with runs up to 200 ft. (61m).
Must be a dedicated line.
Runs over 200 ft, (61m) consult factory.
Propane: 2″ (51mm) ID for 1, 2, or 3 ovens with runs up to 200 ft. (61m).
Must be a dedicated line.
Runs over 200 ft, (61m) consult factory.
2 |
|
|
|
4 | 24" | ||
|
| 610mm | |
| |||
343mm |
|
| |
|
|
|
|
Suggested dimensions are shown; utility code requirements supersede any factors shown.
Figure 2-9. Typical PS540-Series Oven(s)
Installation
GAS SAFETY VALVE
A3/4″ (19mm) ID (inner diameter)
REQUIRED GAS SUPPLY PRESSURE
Natural: 6″ to 12″ water column (13.8 to 29.9 mbar)
Propane: 11.5″ to 12″ water column (28.7 to 29.9 mbar)
SUGGESTED
If space permits, electric and gas service should be located near the control console end of the oven(s) to allow convenient access to safety switches and valves.
USER SUPPLIED ITEMS (Figure
ITEM DESCRIPTION
12″ (51mm) × 2″ (51mm) × 3/4″ (19mm) TEE
2 3/4″ (19mm) × 3″ (76mm) NIPPLE
3 3/4″ (19mm) FULL FLOW GAS SHUTOFF VALVE
4 2″ (51mm) × 3/4″ (19mm) 90° REDUCER ELBOW
5 2″ (51mm) ID GAS SUPPLY PIPE LINE - NATURAL GAS
615 AMP TOGGLE SWITCH - 2 POLE for GAS
17