VI. CONVEYOR REAR STOP AND END STOP INSTALLATION

The minimum gas line pressure at the input side of the full-flow gas shutoff valve, when the oven burner is operating on the high flame, MUST be, for natural gas, 6w.c. (14.9mbar), 1.13 kPa and for propane gas, 11w.c. (27.4mbar) 2.75 kPa. Sufficient pressure must be available to provide for the maximum BTU consump- tion rate for the oven: 116.0 mJ/h, 110,000 BTU/hour for each PS540 Oven. For double oven installations, the BTU/hour requirement for a single oven is doubled. For triple oven installations, the BTU/hour requirement for a single oven is tripled.

Appliance

Connection

(Male Nipple)

90-deg.

ST. Elbow

Union

SECTION 2

INSTALLATION

VI. CONVEYOR REAR STOP AND END STOP INSTALLATION

Locate the conveyor rear stop and end stop in the installation kit. Install the rear stop and end stop at the exit end of the oven. See Figure 2-14.

To Gas Supply Pipe

Full Flow Gas

Shutoff Valve

Flexible Hose

Figure 2-13. Flexible Hose Installation

Conveyor Rear Stop

Middleby

Marshall

Conveyor End Stop

Figure 2-14. Installing Rear and End Stops