Miele CVA4075 installation instructions Plumbing, Connection to the water supply

Models: CVA4075

1 64
Download 64 pages 50.64 Kb
Page 57
Image 57
Plumbing

Plumbing

The machine must be connected to the water supply in accordance with local and national regulations.

The water being used should have the drinking water standards of the respective country where the machine is used.

All units and systems used to deliver the water to the coffee system must conform with the requirements of the respective country.

The machine is designed to be plumbed to a cold water connection.

The machine can be connected without a non-return valve.

The on-site water line must have a water valve to turn the water off if needed. If not present, have a water valve installed by a licensed plumber.

The water faucet must be accessible after installation.

Water pressure on-site: Minimum: 14.5 psi

Maximum: 145 psi, if higher, install a pressure reduction valve.

Suitable 1/4" tubing or copper piping must be supplied for plumbing.

To ensure the best coffee quality, the maximum length of the tubing or copper pipe should not exceed

4 ft. 11" (1.5 m). If too much water remains in the tubing the coffee quality could be affected.

Connection to the water supply

^Disconnect the machine from the electrical supply.

^Remove the water connection cover at the lower rear side of the coffee machine.

^Screw the supplied brass compression fitting, with the ¾" end, tightly onto the water connector of the coffee machine. (Tighten the compression fitting by hand, do not use a tool.) The fitting includes an opening for standard ¼" piping.

^Connect the compression fitting to the water supply.

^Check for leaks.

57