![Automatic switch-off of the Intensive setting](/images/new-backgrounds/65401/6540127x1.webp)
Operation
Automatic switch-off of the Intensive setting
You can set the Intensive setting so that it only runs for 10 minutes before reverting automatically to level III.
To set this option, both the fan and the hob lighting must be switched off and the deflector plate pushed in.
Press the – and + touch controls at the same time for approx. 10 seconds until the first power level indicator lamp lights up in the display.
Then press, one after the other,
Press the + touch control to activate automatic
The indicator lamps for fan power levels I and IV will now light up constantly.
Press the – touch control to deactivate the automatic
Press the On/Off touch control to confirm.
Safety cut-out
–the hob lighting touch control,
–then the – touch control, and
–the hob lighting touch control again.
The indicator lamps for fan power levels I and IV will flash if the automatic
Should the cooker hood be left on, the fan will switch off automatically after 10 hours. The lighting will remain on.
Pressing the On/Off control will switch the fan back on again.
14