Miele DA 3160, DA 3190 installation instructions Condensate trap, Connection for air extraction

Models: DA 3160 DA 3190

1 40
Download 40 pages 53.54 Kb
Page 33
Image 33
Condensate trap

Connection for air extraction

Important:

If the exhaust ducting is to run through rooms, ceiling space etc. where there may be great variations in temperature between the different areas, the problem of condensation will need to be addressed. The exhaust ducting will need to be suitably insulated.

Condensate trap

(optional extra)

In addition to insulating the exhaust ducting, we recommend that a suitable condensate trap is also installed to collect and evaporate any condensate which may occur. Condensate traps are available for ￿ 125 mm or

￿150 mm ducting.

When installing a condensate trap, ensure that it is positioned vertically and if possible directly above the exhaust connection. The arrow on the housing indicates the direction of air-flow.