Replacing the grease filter

Installation

Replacing the grease filter

Set up for extraction mode

 

 

 

 

￿Remove the protective strip around the edge of the grease filter.

Replace the grease filter.

￿To do this, pull the deflector plate out.

￿Turn the grease filter so that the red plastic guides are at the front and facing upwards.

￿Replace the grease filter in the front of the deflector plate, press it upwards and push it in together with the deflector plate. It will slide onto the fixing pins at the back. Finally, push the grease filter back a little more.

￿If the on-site ventilation system does not have a non-return flap, then the non-return flap supplied with the appliance must be fitted in the exhaust socket in the motor unit. Depending on model, the non-return flap may already be fitted.

￿Secure the ventilation ducting over the exhaust socket on the cooker hood using a hose clip.

￿See "Connection for air extraction" for further instructions on fitting the ducting.