Miele G 7804 operating instructions Plumbing, Water inlet

Models: G 7804

1 52
Download 52 pages 22.41 Kb
Page 43
Image 43
Plumbing

Plumbing

Water inlet

^The machine must be connected to the water supply in accordance with local and national regulations.

^The washer is constructed so it may be connected to a supply without an extra non-return valve, unless required by code.

^An acceptable water pressure (flow rate) is 10 - 147 psi. However, the recommended pressure is

25 - 60 psi.

If the water pressure is below 30 psi, the fill time will take longer.

If the "Fill/Drain" fault code "F..E" is displayed, contact the Technical Service Department.

^The machine is supplied to be connected to a standard cold (coded blue) or hot (coded red) water supply to a maximum temperature of 158 °F (70 °C.)

Connect the water intake hoses to the cold and hot water faucets.

If no hot water supply is available, the hot water intake hose with the red marking needs to be connected to cold water by a y-adapter.

For a DI water connection (H2O pure), see the next page.

^Water valves with 3/4" male hose thread are to be provided on site. They should be easily accessible so the water supply can be turned off if necessary.

^The inlet hoses are 5 ½ feet (1.7 m) long, terminating in a 3/4" female hose thread. The water inlet filters in the threads must not be removed.

^Large surface area filters are enclosed in the kit supplied with the machine.

Install these filters between the water valve and the water inlet hose (see illustration in "Machine Care/Cleaning the filters in the water inlet"). The large surface area filter for DI water is made from stainless steel and can be recognized by its matte surface.

,Do not cut the inlet hose or damaged it in any way.

^See the supplied installation diagram.