Miele K 12421 SD The interior lighting, is not working, The floor of the, refrigerator is wet

Models: K 12421 SD

1 48
Download 48 pages 56.42 Kb
Page 30
Image 30
The interior lighting

Problem solving guide

Problem

Possible cause

Remedy

The interior lighting

The lighting switches itself

^ Disconnect the appliance

is not working.

off automatically after

from the mains.

 

approx. 15 minutes if the

 

 

door is left open.

 

 

If it does not come on when

 

 

the door is opened briefly,

 

 

but the temperature display

^ Press the sides of the

 

is working, then the lighting

lamp cover forwards (1)

 

is defective.

 

and unhook the cover (2).

 

 

 

 

^ Unscrew the lamp and

 

 

replace it with a new one.

 

 

Lamp specification:

 

 

220 - 240 V, E 14 cap

 

 

See the old lamp for the

 

 

Wattage required.

 

 

^ Replace the cover by

 

 

clipping it in at the rear

 

 

and then pressing it in at

 

 

the sides.

 

 

 

The floor of the

The condensate drain hole

^ Clean the condensate

refrigerator is wet.

is blocked.

channel and drain hole.

30

Page 30
Image 30
Miele K 12421 SD The interior lighting, is not working, The floor of the, refrigerator is wet, Problem solving guide