Miele PW 6131, PW 6161, PW 6101 Peak load cut off, PC Connection, Load size, Optional modules

Models: PW 6161

1 44
Download 44 pages 15.28 Kb
Page 26
Image 26
Peak load cut off

Optional modules

Peak load cut off

When activating the peak load cut off the heat is turned off and the program is stopped. The display shows:

1

Hot Wash

 

Program stop by peak load function

 

The program continues.

 

i

ü

f

When the peak load function ends the program will continue automatically.

PC Connection

A serial interface is located at the rear of the washer to connect the machine to a PC (Personal Computer).

PC-Operation: Program changes can be made via a PC, or a new program can be downloaded.

Printer-Operation:

It is possible to print out whole programs or parts of programs.

This requires a special Editor Program which is available from the Miele Professional Department.

Load size

If the machine is equipped with a load module, the load weight will be displayed, in

0.5lb increments, while loading the laundry. The maximum laundry weight is displayed next to the selected program.

^Reset with the -> I <- "zero setting" if the weight display does not show "00.0" when the drum is empty.

1

Hot Wash

00.0 /

16 lb

140 °F

Main wash

 

 

 

Rinse

 

e

 

 

+i m k m -> I <-

A

If there was still laundry in the drum when the weight display was reset, the display shows:

1

Hot Wash

- - .-

16 lb

 

 

/

 

140 °F

Main wash

 

 

 

Rinse

 

e

+i m k m -> I <-

A

^Reset again with the -> I <- button.

If the machine is overloaded (wet laundry) the machine calculates after the programs start with the nominal value. This value is saved in the operating data module.

At the end of a program, with the drum stationary, the residual moisture of the laundry is displayed.

1

Hot Wash

 

 

Program end

Residual moisture 60 %

Door can be opened..

 

 

 

m

FC

A

See "Use - Adjust the program" for more information.