5-7. Electrical Service Guide

Input Voltage

Input Amperes At Rated Output

Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes

Circuit Breaker 1, Time-Delay 2

Normal Operating 3

Min Input Conductor Size In AWG

Max Recommended Input Conductor Length In Feet (Meters)

Min Grounding Conductor Size In AWG

Reference: 1999 National Electrical Code (NEC)

1Choose a circuit breaker with time-current curves comparable to a Time Delay Fuse.

2“Time-Delay” fuses are UL class “RK5” .

230

20.5

25

30

14

67

(20)

14

3“Normal Operating” (general purpose − no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and above).