![](/images/backgrounds/280701/bg2d.png)
OM-1594 Page 39
7-11. Overload ProtectionRef. 801 577 / Ref. 800 185-A
YTurn Off wire feeder and
welding power source. Stop
engine on welding
generator.
If fuse opens, unit shuts down. To
replace fuse, proceed as follows:
1 Fuse Holder Cover
2 Fuse F1 (See Parts List)
3 Circuit Breaker CB1
If CB1 opens, the gun drive motor,
gas valve, and contactor will not
operate when trigger is pulled. The
gun drive motor operates in the Jog
mode with CB1 open.
Check for blocked gun liner.
Check for jammed wire, binding
drive gear or misaligned drive rolls
in feeder. Correct problem.
Allow cooling period and manually
reset breaker. Close and latch door.
3
1
2
7-12. Water Flow Switch (Optional For Water-Cooled Models)