Miller Electric XR Control manual Air-Cooled Gun Connections

Models: XR Control

1 72
Download 72 pages 17.93 Kb
Page 21
Image 21

5-3. Air-Cooled Gun Connections

2

7

6

8

3

4

5

 

Left Side

6

1

1 Gun Control Cable

Insert plug into Gun Control receptacle, and tighten threaded collar.

2Gas Hose

3Reed Relay

4Weld Cable

5Weld Cable Terminal In Feeder

Route weld cable from welding power source through reed relay to weld cable terminal in feeder and connect to weld cable terminal.

6Gun Connector

7Gun Securing Knob

8Gun Connector Block

Loosen gun securing knob, and insert gun connector through Wire opening until it bottoms against block. Tighten knob. Close and latch door.

Tools Needed:

9/16, 3/4 in

Ref. 801 577-A / 801 564-E / Ref. 151 666-G

OM-1594 Page 15

Page 21
Image 21
Miller Electric XR Control manual Air-Cooled Gun Connections