7Replacing Parts and Supplies
7-8 CF2002/CF3102
To replace the staple cartridge for FN-8
1Open the front door of the finisher.
2Turn misfeed-clearing dial
clockwise until the removal indicat or
is completely blue.
HIf the dial is turned too far, turn it
counterclockwise to adjust it.
3Slowly pull out the stapler unit as far
as possible.
4Turn dial clockwise until the
staple cartridge moves to a positi on
from where it can be removed.
HIf the dial is turned too far, turn it
counterclockwise to adjust it.
CF2002.book Page 8 Friday, June 13, 2003 9:29 AM