1PRECAUTIONS FOR DEVICES THAT USE R407C REFRIGERANT

Caution

Do not use the existing refrigerant piping.

The old refrigerant and refrigerator oil in the existing piping contains a large amount of chlorine which may cause the refrigerator oil of the new unit to deterio- rate.

Use refrigerant piping made of phosphorus deoxi- dized copper and copper alloy seamless pipes and tubes”. In addition, be sure that the inner and outer surfaces of the pipes are clean and free of hazardous sulphur, oxides, dust/dirt, shaving particles, oils, moisture, or any other contaminant.

Contaminants on the inside of the refrigerant piping may cause the refrigerant residual oil to deteriorate.

Store the piping to be used during installation indoors and keep both ends of the piping sealed until just before brazing. (Store elbows and other joints in a plastic bag.)

If dust, dirt, or water enters the refrigerant cycle, deterioration of the oil and compressor trouble may result.

Use ester oil, ether oil or alkylbenzene (small

amount) as the refrigerator oil to coat flares and

flange connections.

The refrigerator oil will degrade if it is mixed with a large amount of mineral oil.

Use liquid refrigerant to seal the system.

If gas refrigerant is used to seal the system, the com- position of the refrigerant in the cylinder will change and performance may drop.

Use a vacuum pump with a reverse flow check valve.

The vacuum pump oil may flow back into the refriger- ant cycle and cause the refrigerator oil to deteriorate.

Do not use the following tools that have been used with conventional refrigerants.

(Gauge manifold, charge hose, gas leak detector, re- verse flow check valve, refrigerant charge base, vacuum gauge, refrigerant recovery equipment)

If the conventional refrigerant and refrigerator oil are mixed in the R407C, the refrigerant may deterio- rated.

If water is mixed in the R407C, the refrigerator oil may deteriorate.

Since R407C does not contain any chlorine, gas leak detectors for conventional refrigerants will not react to it.

Do not use a charging cylinder.

Using a charging cylinder may cause the refrigerant to deteriorate.

Be especially careful when managing the tools.

If dust, dirt, or water gets in the refrigerant cycle, the refrigerant may deteriorate.

If the refrigerant leaks, recover the refrigerant in the refrigerant cycle, then recharge the cycle with the specified amount of the liquid refrigerant indicated on the air conditioner.

Since R407C is a nonazeotropic refrigerant, if addi- tionally charged when the refrigerant leaked, the com- position of the refrigerant in the refrigerant cycle will change and result in a drop in performance or abnor- mal stopping.

Do not use a refrigerant other than R407C.

If another refrigerant (R22, etc.) is used, the chlorine in the refrigerant may cause the refrigerator oil to de- teriorate.

–3–

Page 5
Image 5
Mitsubishi Electronics PURY-P400 Do not use the existing refrigerant piping, Use liquid refrigerant to seal the system

PURY-P400, P500YMF-C specifications

Mitsubishi Electronics has long been a leader in the HVAC industry, known for its innovative technology and reliable performance. Among its notable offerings are the P500YMF-C and PURY-P400 models, designed to address the diverse needs of commercial and residential applications.

The Mitsubishi P500YMF-C is a high-performance outdoor unit that showcases energy efficiency and advanced refrigerant technology. It employs a sophisticated inverter-driven compressor, which optimizes energy usage by adjusting its speed based on the specific heating and cooling demands of the environment. This flexibility helps to minimize energy consumption while ensuring optimal comfort.

One of the standout features of the P500YMF-C is its ability to provide consistent heating and cooling even in extreme outdoor temperatures. The unit can operate effectively in low-temperature conditions, making it ideal for regions with harsh winters. Furthermore, the system is designed with a robust build, ensuring durability and longevity.

On the other hand, the PURY-P400 is an indoor multi-split system that complements the outdoor unit perfectly. It's designed for versatility and efficiency, capable of accommodating multiple indoor units connected to a single outdoor unit. This feature is particularly beneficial for larger spaces or buildings where different zones require individual climate control.

The PURY-P400 incorporates Mitsubishi's advanced filtration technology, which significantly improves indoor air quality. It features a multi-layer filtration system that effectively removes dust, allergens, and other particulates from the air, ensuring a healthier environment for occupants.

Both systems utilize R-32 refrigerant, which has a lower global warming potential compared to traditional refrigerants. This not only makes them more eco-friendly but also complies with emerging environmental regulations. The ease of installation and operation of these units is another noteworthy characteristic, with intuitive controls and user-friendly interfaces that facilitate seamless integration into existing systems.

In summary, the Mitsubishi P500YMF-C and PURY-P400 represent a fusion of technology, efficiency, and user-centric design. With a range of features aimed at enhancing performance and environmental sustainability, these models are an excellent choice for anyone looking to invest in a reliable and efficient HVAC system. Whether for residential or commercial use, Mitsubishi’s offerings continue to set the standard in comfort and efficiency.