GENERAL INSTALLATION INFORMATION

In planning the installation for the fireplace it is necessary to determine where the unit is to be installed and whether optional accessories are desired. Gas supply piping should also be planned. The following steps represent the normal sequence of installation. Each installation is unique, however, and might require a different sequence.

1.Position fireplace in desired location. Refer to the “Loca- tion of Fireplace” and “Clearances and Height Require- ments,” and “Firebox Framing” sections found in this manual. Note: Be sure all packing material has been removed from underside of the unit.

2.Install canopy and logs per instructions found in this manual. The canopy MUST be installed for safe operation of the unit.

3.Field wire main power supply to units with fan kit. Refer to the “Electrical Section” found in this manual. (Electrical connections should only be performed by an experienced, licensed certified tradesman).

D

F

E

4.Install optional ON/OFF kit on units with milli-volt control. Refer to installation instructions included with the kit and also refer to the “Electrical Wiring” section found in this manual.

5.Plumb gas line. Refer to the “Connecting the Gas” section found in this manual. (Gas connections should only be performed by an experienced, licensed / certified tradesman).

6.Complete finish wall material and/or surround.

 

DFS32NVC

DFS36NVC

DFS42NVC

 

DFS32PVC

DFS36PVC

DFS42PVC

 

 

 

 

A

37"

41"

47"

B

32"

36"

42"

C

16"

18"

18"

D

29"

32"

38"

E

18⅝"

20⅝"

20⅝"

F

23⅜"

27⅜"

33⅜"

G

13¼"

15¾"

15¾"

H

18"

17⅝"

17⅝"

I

29⅞"

34"

40"

J

7⅛"

9¾"

9¾"

K

8"

8¼"

8¼"

L

2¾"

2¼"

2¼"

Figure 2 - Firebox Dimensions with Screen and Log Sets

C

 

 

 

 

1 ¼"

 

 

57/16"

 

I

 

21 ¾"

B

34 ½"

 

 

 

J

2 ½"

 

 

 

 

K

6"

 

 

1 5/16"

A

G

 

 

 

L

H

71D0532

9

Page 9
Image 9
Monessen Hearth DFS32PVC, DFS36NVC, DFS42NVC General Installation Information, Firebox Dimensions with Screen and Log Sets