Monessen Hearth DFS42PVC The fireplace must be installed giving, manual, Fireplace Framing

Models: DFS36PVC DFS36NVC DFS32PVC DFS42PVC DFS42NVC DFS32NVC

1 44
Download 44 pages 55.71 Kb
Page 16
Image 16
The fireplace must be installed giving

FIREPLACE FRAMING

When finishing a custom cabinet, mantel, or other built-in enclosure, the opening size to accommodate the fireplace with trim installed is as follows:

DFS32NVC DFS36NVC DFS42NVC

DFS32PVC DFS36PVC DFS42PVC

K 37⅞"41⅞"47⅞"

J 35⅞"35⅞"35⅞"

 

 

WARNING

WARNING

 

The fireplace must be installed giving

 

full consideration to the clearance and

 

height requirements identified in this

 

manual.

 

 

K

J

Figure 13 - Custom Cabinet

1.Bend out the nailing flanges located on each side of the firebox.

2.Slide the firebox into prepared framing or position firebox in its final position and frame later.

3.Level the firebox by checking the top edge of the firebox. Shim if necessary.

4.Anchor firebox to the side framing members using 8d nails or other suitable fasteners. Refer to Figure 14.

5.The canopy must be installed for safe operation of the heater. Refer to page 12 for canopy installation details.

Nail Sides

Through Nailing

Flanges

Figure 14 - Location of Nailing Flanges