CLEARANCES AND HEIGHT REQUIREMENTS

10" or less

Heat

Resistant

Material

12" min. 28"

Heater in

 

Fireplace or

Example: The bottom of the mantel may project from the wall a maxi-

Firebox

 

mum of 10" at a minimum of 28" above the opening.

Figure 9 - Minimum Mantel Clearance with No Hood — TPB24/30

7"

 

6"

 

21/2"

141/2"

4"

8"

 

Figure 10 is an example of an unsafe mantel installation. This mantel projects 4" at 8" above the opening, exceeding the maximum acceptable distance of 21/2" The mantel also proj- ects 7" at 141/2" above the opening, exceeding the maximum acceptable distance of 6".

If your mantel profile is unsafe, you may either:

Raise the mantel to an acceptable height

OR

Remove the mantel

Figure 10 - Minimum Mantel Clearance with Hood - TPB24/30

(Example of Unsafe Installation)

70D0004