13 - 28 Symbol MiniScan MSXX07 Series Integration Guide
Setup Field(s)Send Data (continued)Send Next 19 Characters
Send Next 20 Characters
Table 13-2
Setup Field(s) Definitions
Parameter Description Page
Move Cursor
Move Cursor To a Character Scan the
Move Cursor To Character
, then any printable ASCII
character from the
Alphanumeric Keyboard on page 13-88
. This
moves the cursor to the position after the matching character. If the
character is not there, the rule fails and ADF tries the next rule.
13-29
Move Cursor to Start of Data Scan this bar code to move cursor to the beginning of the data. 13-29
Move Cursor Past a Character This action moves the cursor past all sequential occurrences of a
selected character. For example, if the selected character is ‘A’, then
the cursor moves past ‘A’, ‘AA’, ��AAA’, etc. Scan the
Move Cursor Past
Character
, then select a character from the
Alphanumeric Keyboard
on page 13-88
. If the character is not there, the cursor does not move
(i.e., has no effect).
13-29
Skip Ahead “N” Characters Scan one of these bar codes to select the number of positions ahead
to move the cursor. 13-30
Skip Back “N” Characters Scan one of these bar codes to select the number of positions back to
move the cursor. 13-31
Send Preset Value Send Values 1 through 6 by scanning the appropriate bar code. Set
these values using the prefix/suffix values.
Value 1 = Scan Suffix
Value 2 = Scan Prefix
Values 3-6 are not applicable
13-31